AcidLab Robokop - X0x-style trigger sequencer
Provides Trigger sequencer
50 HP (254 mm), 80 mA @ +12V, 20 mA @ -12V, 0 mA @ +5V
Made by AcidLab.
Front panel
b c d e f a o o o o o o o o o o o o o o o o a=Start/Stop b=Scale c=Inst./Sel. d=Leng./Shuf. e=Clear f=Write/Next
Labels of switch positions and rotary detents
- Prog (rotary switch, clockwise)
- 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- Mode (rotary switch, clockwise)
- Track write, Track play, Pattern play, Tap write, Step write, Pattern play
Usage
Copy & paste patterns (Pattern Play Mode)
To copy a pattern to the paste buffer, hold the Inst/Select button while pressing one of the pattern buttons (1-16).
To override a particular pattern with the contents of the paste buffer, optionally select the desired pattern group with the detented rotary, and hold the Write/Next button while pressing the desired pattern button (1..16).”
External links
Schneiders Laden has a page about this module.